<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-13 06-28-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
7.0 kHz 3.3 kHz 84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 18897 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,2 dBr 3,24 dBr 3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Fantasia - Tanssisarja G-Duurissa (Lawes William, Lawes) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 0,0053 Acquired: 2025/02/13 6.27.40 Total samples: 18897 Equivalent time: 0:15:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,8 dBr MIN: 2,2 dBr AVE: 3,24 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2025/02/13 6.27.40) 06.14 06.16 06.18 06.20 06.22 06.24 06.26 -1 0 1 2 3 4 Pm [dBr]